SENA ProBee-ZU10 User Manual
Page 63

63
ProBee-ZU10 User Guide Rev.1.5
7.4.6
S56
Description
Get/Set the end-device poll period in seconds. Adaptive polling may allow the end-
device to poll more rapidly for a short time when receiving RF data.
Execute
ATS56?<CR>
ATS56=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default
5
Range
0 - 10000
7.5
Sink
7.5.1
S61
Description
Get/Set the sink node and the sink advertise period in seconds. When a node is
defined as a sink, it can multicast its address to the rest of the network in this period. If
set to 0, sink advertise is disabled.
Execute
ATS61?<CR>
ATS61=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default
0
Range
0 – 10000
7.5.2
S62
Description
Get/Set the period to send Many-to-One Route Request. Many-to-One Route Request
(MTOR) creates routes from every node in the network back to this node. It is useful
when this node acts as a sink node.
Execute
ATS62?<CR>
ATS62=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default
0
Range
0 – 10000