Centripro™ control box – Xylem II 231 P INSIDER User Manual

Page 7

Advertising
background image

7

4/07

CENTRIPRO™ CONTROL BOX

CONNECTIONS

1. Remove the cover from the front of the 3-wire CentriPro™ control box.

2. Remove the yellow wire from the terminal strip at L2.

3. Remove the black wire connecting L1 and the capacitor completely from the box.

4. Press the PumpSaver

®

onto the L1 and L2 terminals.

5. Reconnect the yellow wire to L2 on the PumpSaver

®

.

6. Connect the blue wire attached to the PumpSaver

®

to the dual-lug terminal (with the black wire)

of the capacitor.

Figure 5: CentriPro™ Control Box with the Model 231-P-Insider Installed