3. Specifications and Order Numbers

Specifications

Oxix

®

Transmitter

Accuracy

+/- 0,1% of reading

Measuring input

RS 485

Analog output

One active 4 - 20 mA, galvanically isolated (max. load 800

W)

Digital outputs

One voltage-free electromechanical relay (max. 50 V DC / 1 A)

One optically isolated MOSFET relay (max. 50 VAC / V DC / 120 mA)

Digital inputs

One, max. 30 V DC, < 5 V DC = 0(low), > 10 V DC = 1(high),

pulse length > 100 ms

Communication

MODBUS

®

RTU-mode, 9600 baud, 2-wire RS 485, slave-mode

Interface

RS 485 for connection to Display Unit or PLC

Power supply

10 - 30 V DC, or 24 V AC, 50 / 60 Hz ± 10 % or

115 V AC, 50 / 60 Hz ± 10 % or

230 V AC, 50 / 60 Hz ± 10 %

Power consumption

Max. 10 W

Cabinet material

Polycarbonate, glass reinforced

Enclosure rating

IP 67, NEMA 6

Temperature range

- 20 … 60 °C

Weight

1,1 kg

Display Unit

Enclosure rating

Dust and waterproof IP 67, NEMA 6 (when mounted on converter)

Housing material

Polycarbonate, glass reinforced

Protection lid

Transparent polycarbonate

Display

White backlit LCD-display (64 x 128 pixels) with softkeys

Indication

Indication measurement, configuration and graph

Clock

Real-time clock with built-in battery backup

Communication

MODBUS

®

RTU-mode, 9600 baud, 2-wire RS 485, master-mode

Interface

RS 485

Memory

256 Kb Flash memory, 20.000 entries with date, time and value

Interface

USB 1,1 type mini B, Female

Temperature range

- 20 … 60 °C