Gotham CANDÉO LED User Manual
Candéo, Led operations manual
Part No. CJ520348
©2007 Gotham
1/07
CANDÉO
®
LED OPERATIONS MANUAL
CANDÉO
®
LED OPERATIONS MANUAL
This Candéo
®
LED operations manual provides instructions for setting up and programming this
product. Please contact Gotham Technical Support at
or 1-800-
315-4982 with any additional questions.
ETHERNET CABLE INSTRUCTIONS
NETWORKING INSTRUCTIONS (MULTIPLE UNITS CONNECTED/CONTROLLED TOGETHER)
The 11 feet of Ethernet cable provided with the housing may be used to network multiple LED drivers
together. If longer lengths of cable are required, it may be purchased at most electronics stores.
(Ethernet cable type: CAT5, RJ45).
The first driver in the network will act as the master. If you are using an LFVRS 9-button or DMX512
external LED driver control (provided by others), the Ethernet cable from the control will be plugged into
the “Network DMX512 In” port on the master unit only (see Figure 1). If you are not using an external LED
driver control, the master driver can be manually programmed by setting the dials located on the top of
the driver. It is recommended that the driver is set prior to installing the housing (see manual
programming instructions on page 3). The Ethernet cable on the master driver should be plugged into
the “Network DMX512 Out” port (see Figure 1). The next driver in the network will behave as a satellite.
Plug the cord from the master into the “Network DMX 512 In” port of the satellite. Continue this process
until you have reached the last driver in the network (MAX 128 drivers per network).
ETHERNET CABLE INSTRUCTIONS
NON-NETWORKING INSTRUCTIONS (SINGLE UNIT/INDIVIDUALLY CONTROLLED UNITS)
If you are installing one unit and do not intend to use an LFVRS, 9-button or DMX512 external LED driver
control (provided by others), you will not need the Ethernet cable provided with the housing. The LED
driver can be manually programmed by setting the dials located on the top of the driver housing. It is
recommended that the driver is set prior to installing the housing (see manual programming instructions
on page 3). If you are installing multiple units and the LED drivers are individually controlled by an
external control, the Ethernet cable will run out of the control and into the “Network DMX512 In” port for
each unit (see Figure 1). If you should require longer lengths of cable than the 11 feet provided, it may be
purchased at most electronics stores (Ethernet cable type: CAT5, RJ45).
1
Figure 1
NETWORK DMX512 OUT
NETWORK DMX512 IN
CONNECT TO LED
MODULE