Gorman-Rupp Pumps 03A52-B 1327255 and up User Manual
Page 29
0 SERIES
OM-01177
MAINTENANCE & REPAIR
PAGE E - 10
add SAE No. 30 non‐detergent
oil through the hole
for the air vent (16). Do not over‐lubricate. Over‐lu
brication can cause the bearings to over‐heat, re
sulting in premature bearing failure.
NOTE
The white reflector in the sight gauge must be posi
tioned horizontally to provide proper drainage.
Under normal conditions, drain the bearing hous
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con
tinuously or installed in an environment with rapid
temperature change.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory for
the recommended grade of oil.