Installation cont, Table iii - model 441 charger light indications – Liberty Pumps 441 User Manual

Page 9

Advertising
background image

INSTALLATION cont.

Red LED - power is present

Yellow LED - Prequalification test stage is complete and testing or charging in process

Green/Occasional Yellow - Charger turns on intermittently to maintain proper charge

Green LED -Charging complete

Green/Yellow LEDs Alternately Flashing - System is in Error Mode (see Table II, Page 10)

NOTICE: For more detailed information, see “Charger Operation” on page 10.

Figure 9 – Model 441 Charger LED Panel

TABLE II - Model 441 Charger Error Table (Green and Yellow LEDs will flash alternately)

Error Description

Possible Causes

Fix

The Battery Failed Pre-

Qualification Test

The battery is highly sulfated


The charger is connected to a six-volt
battery

Replace the battery with a 12-Volt deep-cycle
marine battery

Replace the battery with a 12-Volt deep-cycle
marine battery

Battery Over-Voltage

The Charger is connected to a 24 Volt
Battery

Replace the battery with a 12-Volt deep-cycle
marine battery

Charge Time Monitor

Battery took too long to complete its charge:
A. Load applied (e.g. the pump motor
started) during charging

B. The battery ampere-hour rating is too
large (Max. 96 ampere-hours)

Be sure pump cannot start during charging; reset
the charger


Replace with correct size battery (see Page 4)

Excessive Battery Drain

Pump motor ran during charging (that is,
with the main A.C. power ON), causing the
system to shut down

Check primary sump pump. The BBU generally
runs only when the main A.C. power is out. If there
has not been any power outage and the BBU has
run, the primary pump itself may have failed

Reverse Battery

Connection

Charger is connected backwards to the
battery. (That is, Charger (+) to Battery (-)
and vice versa)

Reconnect Charger (+) to Battery (+)/(-) to (-)

Battery Overheated

Cells in an old battery may deteriorate with
age

Replace battery with a 12-Volt deep-cycle marine
battery

TABLE III - Model 441 Charger Light Indications

Charger Light

On/Off/Flashing

Indicates

All Lights

Off

System is not receiving AC power

Power (Red Light)

On

Off

System is receiving AC power

System is NOT receiving AC power or battery leads are reversed

Charging (Yellow Light)

Flashing 1x/Second


On, steady


Flashing alternately with
green light

Charger is running “Pre-Qualification” test (this lasts 45 seconds to 6
hours)

Charger is either in “Constant Current” or “Constant Voltage” stage.
This may last up to 96 hours

System is in an ERROR mode (see Table II, above)

Charged (Green Light)

On, yellow light Off

Flashing alternately with
yellow light

Battery is fully charged

System is in an ERROR mode (see Table II, above)

©Copyright 2009 Liberty Pumps Inc. All rights reserved 9