Commissioning
© Gardner Denver Deutschland GmbH
21 / 32
610.44434.40.000
6 Commissioning
WARNING
Improper use of the unit can result in serious or
even fatal injuries!
Have you read the safety precautions in Chapter 1,
"Safety", Pg. 3 f.? Otherwise you many not carry
out any work with or on the pump-motor unit!
WARNING
Danger from rotating parts (external fan, impeller,
shaft): Cutting/cutting off of extremities,
Grasping/winding up of hair and clothing!
Danger due to vacuum and gauge pressure:
sudden escape of fluids (skin and eye injuries),
sudden drawing in of hair and clothing!
Danger due to escaping fluid: Burns!
Start-up and operation only under the following conditions:
The pump-motor unit must be completely
assembled. When doing so, pay particular
attention to the following components:
–
the vacuum pump/compressor cover,
–
the muffler on inlet and discharge
connections,
–
the fan guard.
The pipes/hoses must be connected to inlet
and discharge connections.
Inlet and discharge connections and the
connected pipes/hoses may not be closed,
clogged or soiled.
Check the mounting elements, connections
of the pipe/hose connections, lines, fittings
and containers for strength, leaks and firm
seating at regular intervals.
6.1 Preparation
WARNING
Danger from closed connections!
With closed/soiled intake or discharge
connections vacuum or gauge pressure results
in the pump-motor unit.
This can overheat and damage the drive motor
winding.
Before start-up, make sure that the inlet and
discharge connections are not closed, clogged
or soiled!
CAUTION
Before starting up again after a longer standstill:
Measure the insulation resistance of the motor.
With values ≤ 1 kΩ per volt of nominal voltage,
the winding is too dry.
Measures before start-up:
If a shut-off device is installed in the discharge
pipe:
Make sure that the unit is NOT operated with
the shut-off device closed.
Before starting up the pump-motor unit,
observe the values specified on the rating
plate. Specifications on the drive-motor
nominal current apply at a gas entry and
ambient temperature of +40° C [104°F].
Adjust the motor circuit breaker to the drive-
motor nominal current.
Check direction of rotation:
The intended rotating direction of the shaft is
marked with arrows on the vacuum
pump/compressor housing (Fig. 1, Pg. 2,
Item. 7).
The gas delivery direction is marked with
arrows on the inlet and discharge connections
(Fig. 1, Pg. 2, Item 6).
Make sure the pipes/hoses on the inlet and
discharge connections are properly
connected.
Switch the pump-motor unit on briefly and
then off again.
Compare the actual rotating direction of the
external fan with the intended shaft rotating
direction indicated with the arrows shortly
before the pump-motor unit comes to a
standstill.
If necessary, reverse the direction of rotation
of the motor.