ABUS FU9080 Privest Wireless Outdoor Siren User Manual

Page 22

Advertising
background image

22

User Menu

Diagnostics
In the Diagnostics menu, you can test the functioning of trained sounders.
To performe diagnostics

1. The system must be deactivated. Press the star button

[

*

]

to access

the user menu and then [4] for the Maintenance menu option.

2. Enter the programmer PIN: In the factory setting, this is 0133.
3. Press Enter [#].
4. Press [7][1] to access the sounder test menu.
5. Enter the ID number of the sounder you want to test. Press Enter [#].

The system now tests communication with the sounder and checks the state
of the wireless sounder batteries and the audible/visual alarm.

6. Press the arrow buttons to see the result.

IMPORTANT:

The test can also be started with the Upload/Download software.

Maintenance

Quick-Key Menu

option

[4][7][1]

Siren Diagnostics

Speakers batteries voltage: Shows the strength of the battery for the
audible/visual alarm.
Radio batteries voltage: Shows the strength of the battery for the
wireless transmitter.

Siren Version

Press [7] [2] to see the sounder version of the selected sounder.

Maintenance

Quick-Key Menu

option

[4][7][2]

Siren Version

Φ Sounder part number:
F=Frequency (868MHz / 433MHz) V=Siren type (Internal/External),
C= lens Color
Φ Sounder software version
Φ Sounder software date
Φ Sounder software checksum

Advertising