Model k576, Portable load bank, Specifications – Atec Avtron-K576 User Manual

Page 2: Outline drawing

Advertising
background image

LOAD CONNECTON

TERMINALS

SCREENED

AIR EXHAUST

LIFTING

HANDLES

(BOTH ENDS)

SCREENED

AIR INLET

(BOTH SIDES)

CONTROL

SWITCHES

CUSTOMER

CABLE ENTRY

(3.00 [76.00] DIA.)

28.00

[711.00]

27.00

[685.00]

24.00

[609.00]

3.50

[88.00]

3.50

[88.00]

4.00 [101.00]

All dimensions are in inches [millimeters]. Specifications subject to change without notice.

SPECIFICATIONS:

CONSTRUCTION: The load bank is contained in a rugged

aluminized steel enclosure, with two rigid and two lockable

swivel casters mounted at the corners, and four lifting handles

provided for simplified handling.

CONTROL POWER: Control power is derived from an exter-

nal 120 volt, single phase, 60 Hz power source. A line cord

is included with the load bank for quick disconnect.

BLOWER: A heavy duty, reliable, industrial blower is used

for cooling the resistive elements. This 1/4 HP device oper-

ates from the same 120 volt, single phase, 60 Hz power

source as the load bank control circuit.

RESISTIVE ELEMENTS: Made of a chromium

alloy, the resistive elements are specially

wound and continuously supported

in the cooling air stream. They are de-

signed to operate at one half of their

rated temperature rating for more

stable loading and longer life without the need for a cool

down period.

CONTROL PANEL: It includes a POWER ON-OFF switch,

a power status indicator light, an ON-OFF switch for each

load step, a MASTER LOAD ON-OFF switch for applying

or removing all selected load steps, and a BLOWER FAIL

indicator light.

PROTECTIVE FEATURES: The control circuit is fuse pro-

tected and the load circuit is disabled by a differential

pressure air switch if insufficient cooling air is detected.

WEIGHT: Approximately 160 lbs. [73 kg]

Model K576

Portable Load Bank

6255 Halle Drive • Cleveland, Ohio, U.S.A. 44125-4615 • 216.573.7600 • FAX 216.573.5953

www.avtronloadbank.com • [email protected]

Bulletin 273 • Rev. C

OUTLINE DRAWING:

K576 LOAD CAPACITY RATINGS:

Total Load Amps

Volts DC

Load Steps in Amps

500

52

25, 25, 50, 100, 100, 100, 100

500

52

2.5, 5, 5, 12.5, 25, 50, 100, 100, 100, 100

Quality System Certified to ISO 9001