Df868 specifications, Ge sensing, Clamp-on ultrasonic flow transducers – Atec Panametrics-Olympus-DF868 User Manual

Page 5

Advertising
background image

GE

Sensing

DF868
Specifications

Storage Temperature
-67°F to 167°F (-55°C to 75°C)

Standard Inputs/Outputs
Two 0/4 to 20 mA isolated outputs, 550 S maximum load

Optional Inputs/Outputs
There are six additional slots available for any
combination of the following I/O boards:

• Analog outputs: Select up to three additional output

boards, each with four isolated 0/4 to 20 mA outputs,
1000 S maximum load

• Analog inputs: Select up to three boards of one of the

following types:
- Analog input board with two isolated 4 to 20 mA

inputs and 24 V loop power

- RTD input board with two isolated, three-wire,

RTD inputs; span -148°F to 662°F (-100°C to 350°C);
100 S

• Totalizer/frequency outputs: Select up to three

totalizer/frequency output boards, each with four
outputs per board, 10 kHz maximum. All boards allow
software-selectable functioning in two modes:

- Totalizer mode: Pulse per defined unit of parameter

(e.g., 1 pulse/gal)

- Frequency mode: Pulse frequency proportional to

magnitude of parameter (e.g., 10 Hz = 1 gpm)

• Alarm relays: Select up to two boards of one of the

following types:

- General purpose: Relay board with three Form C

relays; 120 VAC, 28 VDC maximum, 5 A maximum;
DC 30 W maximum, AC 60 VA

- Hermetically sealed: Relay board with three

hermetically sealed Form C relays; 120 VAC, 28 VDC
maximum, 2 A maximum; DC 56 W maximum,
AC 60 VA

Digital Interfaces
• Standard: RS232
• Optional: RS485 (multiuser)
• Optional: Modbus® RTU
• Optional: Modbus TCP
• Optional: OPC server
• Optional: Ethernet

Site Parameter Programming
• Menu-driven operator interface using keypad and

"soft" function keys

• Storage for 10 sites

Data Logging
Memory capacity (linear and/or circular type) to log over
43,000 flow data points

Display Functions
• Graphic display shows flow in numerical or graphic

format

• Displays logged data and diagnostics

European Compliance
System complies with EMC Directive 89/336/EEC,
73/23/EEC LVD (Installation Category II, Pollution
Degree 2)

Clamp-On Ultrasonic Flow
Transducers

Temperature Ranges
• Standard: -40°F to 300°F (-40°C to 150°C)
• Optional (overall range): -310°F to 572°F

(-190°C to 300°C)

Mountings
Stainless steel chain or strap, welded or magnetic
clamping fixtures

Area Classifications
• Standard: General purpose
• Optional: Weatherproof Type 4/IP65
• Optional: Explosion-proof Class I, Division 1,

Groups B,C&D; Class II, Groups E,F&G; Class III

• Optional: Flameproof

II 2 G EEx md IIC T6-T3

• Optional: Submersible