Wiring

Turn the splices upward and push them carefully back through the hanger bracket

into the outlet box. Spread the wires apart, with the grounded wires on one side of

the outlet box and the ungrounded wires on the other side of the outlet box.

Refer to CAUTION c.1 on pg. 2

10

M0068-01 • 04/22/13 • © Hunter Fan Company

FR

OM

RECEIVER

FR

OM CEILING

FR

OM

CEILING BRA

CK

ET

Using an orange wire

connector from

the hardware bag,

connect the 3 grounding

wires (green, green/

yellow stripe, or bare

copper) coming from the

ceiling, downrod, and

hanging bracket.

green/y

ello
w str

ipe

(g

rounding)

green/y

ello
w str

ipe

green/yellow stripe

whit

e

black

blue

whit

e (c
ommon out)

black (fan out)

blue (ligh

t out)

Note: To connect the wires,

hold the bare metal leads
together and place a wire

connector over them, then twist

clockwise until tight.

Using the blue wire

connectors from the remote

control hardware bag,

connect the white wire

from the receiver (marked

“common out”) to the white

wire from fan. Connect the

black wire from the receiver

(marked “fan out”) to the

black wire from the fan.

Connect the blue wire from

the receiver (marked ”light
out”) to the blue wire from

the fan. The red wire from

the receiver will not be used,

it has a pre-installed wire

terminator.

FRO

M FAN

FROM FAN

FRO

M RECEIVE

R

Using an orange wire

connector from

the hardware bag,

connect the black wire

(ungrounded) from the

ceiling to the black wire

from the receiver (marked

“live in”). Connect the

white wire (grounded)

from the ceiling to

the white wire from

the receiver (marked

“neutral in” or

“common in”).

FR

OM CEILING

black (ung

rounded)

whit

e (g
rounded)

whit

e (neutr

al in)

black (liv

e in)

Advertising