8 - routine maintenance – CEMB USA C88 (A) User Manual
Page 39

I 0607 - 39
GB
Err.59
Radial and lateral Sonar readout error.
Lateral and radial Sonar values are insuffi -
cient for correct measurement of radial and
lateral eccentricity.
1.
Check points Err. 55
2.
Check points Err. 57
Err.65
Printer timeout
1. Check that a printer is present.
2. Check the code of the processor card.
3. Check the printer <-> processor card connection.
4. Run the printer test function.
Err.66
Printer buffer error
1.
Reset the printer.
2.
Repeat the print function.
8 - ROUTINE MAINTENANCE
8.1 - Scheduled maintenance
Switch off the machine from the mains before carrying out any operation.
8.2 - Replacing fuses
Remove the weight holder shelf to gain access to the power supply board where the 4 fuses are located (
Exploded Drawings). If fuses require replacement, use ones of the same current rating. If the fault persists, contact
Technical Service.
NONE OF THE OTHER MACHINE PARTS REQUIRE MAINTENANCE.
►
►