Datamax-O'Neil H-Class Linear Scanner Option User Manual

Page 12

Advertising
background image

10

Scanner Menu Item

Description

REDUNDANCY LEVEL

Ensures bar code integrity by specifying a redundant read count.

(1X – 6X)

READ BARCODE 2X

This count (1 – 6) sets the number of consecutive and identical decodes
that must occur for a bar code to pass.

AUTO

Operation switches to MIN READABLE HEIGHT.

IGNORE NO DATA

Allows an override of the verification function, where:

DISABLED

Checks for correct bar code data in the bar code(s).

ENABLED

Ignores the data present in the bar code(s).

SET DEFAULTS

Restores the Linear Scanner settings to the factory default values.

YES / NO

Selecting YES will return these settings:

MODE = Auto
BARCODES = All, except IATA and codes with certain addendums
BAR CODE COUNT = 00 (Auto Mode)
MIN READABLE HEIGHT = Disabled
REDUNDANCY LEVEL = 2X
IGNORE NO DATA = Disabled

To change FAULT HANDLING settings –

1) Press

MENU. Press DOWN or UP to scroll to SYSTEM SETTINGS, and then press ENTER.

2) Scroll to FAULT HANDLING and then press ENTER. (See table below for listing.)

3) When finished, press EXIT and then YES at the SAVE CHANGES prompt to complete setup.

Fault Handling Menu Item

Description

LEVEL

Determines the amount of interaction required to proceed after a fault.

NO REPRINT

Printing stops and a fault message is displayed. Following correction of the
problem, FEED must be pressed to clear the fault, but the label in process is
not reprinted.

STANDARD

Printing stops and a fault message is displayed. Following correction of the
problem, FEED must be pressed to clear the fault then the label in process is
reprinted.

VOID AND RETRY

Depending upon the RETRY COUNT (see below), one of the following:

If the count has not been exceeded, VOID is printed (see VOID
DISTANCE) on the failed label and reprinting automatically occurs;

If the count has been exceeded, printing stops and a fault message is
displayed. Following correction of the problem, FEED must be pressed to
clear the fault before the label in process is reprinted; or,

If CANCEL is pressed, reprinting is optional: to reprint, press NO; or, to
cancel the reprint, press YES (and press YES again to cancel the batch.)

(continued)

Advertising