7) NETira CT will display a

message indicating the process
has finished.


In case of any error, a FAILED
CALIBRATION message will be
displayed. Repeat the process.






8) To confirm changes, observe

that Gap Back Value and Gap
Paper Value have changed.












Procedure for Black Mark Media:

(be sure the printer is set to sense Black Mark media, see Section 3.4.1).

1) Click on the ‘Sensor Calibration’

printer component.





2) Click the ‘Manual Media’ button

to start the manual calibration
process.


Follow the instructions on the
following screen.






3) Select the Reflective radio

button then click ‘OK’.