4 TECHNICAL

SPECIFICATIONS

Supply voltage

230 V / 50 Hz

Protection index

wall version: IP 65

mobile version: IP44

Dosage rate

0,01 % à 99,9 %

Sensor resolution

< 250 impulses per litre

Output signal

impulses for the consumption of water and active product

Flow impulses

transistor output, max. 30 V, 100 mA

Water pressure

see the versions table

Authorised flow

see the versions table

Display

LCD 15 x 60 mm

Internal counters

daily and totaliser for water and active product

Approval/Certificate

all the elements conform to the CE

Weight of wall system

approx. 6.95 kg

Weight of mobile system

approx. 18.2 kg, empty

5 MAINTENANCE AND TROUBLESHOOTING

Regularly check:

The integrity of electrical supply cables and all electrical connections.

The integrity of the appliance housing (no dent or deterioration of any kind that

could affect the watertightness).

The tightness of sealing parts (cable seals, covers, etc.).

5.1 Maintenance

After dosing with viscuous or crystallised liquids, rinse the pump with clean water.

After rinsing leave water in the pump head.

If necessary, remove the dosing pump anti-return valves manually to clean them (see the type
7800 dosing pump user manual).

• Replace the anti-return valves carefully.
• Fit the parts in the correct order.
• Tightening should be by hand only.