Contaminant reduction performance – Hydrotech 1240 Series ADVANCED REVERSE OSMOSIS WATER TREATMENT SYSTEMS User Manual
Page 4
II
CONTAMINANT REDUCTION PERFORMANCE
Hydrotech Performance as tested by an outside agency is shown below. Past test results may not be indicative of current performance
and your results may vary depending on conditions.
MODELS AND SYSTEM CONFIGURATIONS
Table 1
CONDITIONS FOR USE
Table 2
OPTIONS AND ACCESSORIES
MODEL
DESCRIPTION
STORAGE
TANk
# OF
VESSELS
STORAGE
TANk
CAPACITY
LITRES (GAL)
VESSEL 1
VESSEL 2 VESSEL 3
VESSEL 4
DAILY
PRODUCTION
RATE
2
L/DAY
(G/DAY)
EFFICIENCY
RATING
3
%
RECOVERY
RATING
4
% MONITOR
6
4VTFC09G-PB
Plastic/Metal
4
6.81 (1.8)
Sediment Filter
Carbon
Filter
TFC
1
Membrane
Carbon
Filter
15.5 (4.1)
12.8
35
Smartap®
Push
Button
4VTFC25G-PB
Plastic/Metal
4
7.19 (1.9)
Sediment Filter
Carbon
Filter
TFC
1
Membrane
Carbon
Filter
29.1 (7.7)
8.2
18
4VTFC50G-PB
Plastic/Metal
4
6.81 (1.8)
Sediment Filter
Carbon
Filter
TFC
1
Membrane
Carbon
Filter
34.44 (9.1)
4.8
16.7
4VTFC75G-PB
Plastic/Metal
4
7.19 (1.9)
Sediment Filter
Carbon
Filter
TFC
1
Membrane
Carbon
Filter
49.58 (13.1)
5.7
15.3
SOURCE WATER SUPPLY PROFILE
ChEMICAL PARAMETERS
MAx MG/L
Community/Private
Chlorinated/Non-Chlorinated
Hardness (CaCO3 )
<170 (10 gpg)
Feed Water Pressure(5)
242-690 kPa (35-100 psig)
Iron (Fe )
<0.1
Temperature
4°-38° C (40°-100° F)
Manganese (Mn)
<0.05
pH Range
3.0 - 11.0
Hydrogen Sulfide (H2S )
0.00
Maximum TDS Level
2000 mg/L
Residual Chlorine (Cl2)
<2.0
Turbidity**
<1.0 NTU
** Nephelometric Turbidity Unit
*** Silt Density Index: Value stated in SDI units.
Maximum SDI***
<4.0
NOTES:
1. TFC refers to reverse osmosis membranes constructed from a THIN FILM COMPOSITE
2. The daily production rate is the volume of product water produced by the system per day and is determined by testing in accordance with the procedure outlined
in NSF/ANSI Standard 58.
3. System’s Efficiency rating as verified by testing in accordance with NSF/ANSI standard 58. Efficiency rating means the percentage of the influent water to the system that is available to
the user as reverse osmosis treated water under operating conditions that approximate typical daily usage.
4. System’s Recovery rating as verified by testing in accordance with NSF/ANSI Standard 58. System’s Recovery rating means the percentage of the influent water to the membrane portion
of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
5. PRESSURE REGULATOR IS RECOMMENDED FOR FEED WATER PRESSURES EXCEEDING 552 kPa (80 psig)
6. SMARTAP® PUSH BUTTON MONITOR. Indicator lights located on the module cover report system status.
PRODUCT WATER FAUCETS
BOOSTER PUMP
Faucets will be supplied as Air Gap.
A booster pump may be used if system pressure is below 242 kPa (35 psi).
Pump should be placed near RO Module and installed in feed water line just before it enters Module.