Continental Industrie Model - 020 User Manual
Blower model 020, I - blower housing
Values, dimensions and reference in this brochure are approximate and intended as guide only, not for construction and are subject to change without notice
DETAILED ENGINEERING DESCRIPTION - CONTINENTAL INDUSTRIE
DEB020EN – 04/2010
1/4
DETAILED ENGINEERING DESCRIPTION AND MECHANICAL
FEATURES OF CONTINENTAL INDUSTRIE MULTISTAGE CENTRIFUGAL
BLOWER MODEL 020
I - BLOWER HOUSING
The centrifugal blower housing consists of an inlet head with special feature to direct air to
inlet of first impeller and outlet head of special design to eliminate friction and multiple
intermediate sections. These parts are made in cast aluminium according to rigid
Continental Industrie specifications, extreme care to be exercised in assembly of
interlocking cast aluminium intermediate sections and annular diffusers (baffles).
The entire assembly is securely held together actually with multiple tension rods which bind
the entire housing into a solid integral unit.
1.0 Inlet
head
1.1 Flange connection DN 150, PN 10 (6”)
1.2 Cast aluminium EN-AC-42000 (ASTM 360.1)
1.3 Minimum wall thickness: 5 mm (0.20”)
1.4 Can be supplied in various flange positions relative to the vertical centre line in
increments of 90° (option)
2.0 Outlet
head
2.1 Flange connection DN 125, PN 10 (5”).
2.2 Cast aluminium EN-AC-42000 (ASTM 360.1)
2.3 Minimum wall thickness: 5 mm (0.20”)
2.4 Can be supplied in various flange positions relative to the vertical centre line in
increments of 90° (option)
3.0 Intermediate
section
3.1 Cast aluminium EN-AC-42000 (ASTM 360.1).
3.2 Each intermediate section is cast in one piece
4.0 Bearing
housing
The outboard bearing housings are cast aluminium and bolted to the outside of the head
sections insuring cool operation of bearings.
4.1 Cast aluminium EN-AC-42000 (ASTM 360.1).
4.2 Has cast fins to improve rigidity and increase heat dissipation
4.3 Felt joint seal.
4.4 Provided with 2 tapped holes in the housing flange to act as bearing puller.
N.B.: When the inlet air or gas temperature is too high, we can adapt as option special
bearing housings with a water or air cooling system (technical drawing on request).