Laurel Electronics LTS6 - Manual User Manual
Page 8
-
- 8 -
SETTING UP BASIC OPERATION
Under the
Input+Display
tab, select 000.00 Secs for
Time Out
. Ignore
Signal Input
,
Gate Time
,
Filter
, and
Power-On Total
, as these parameters do not apply to the serial input transmitter.
Under
Display
, select
Remote A
,
Remote S
or
Remote C
. These items correspond to the Remote A,
Remote S and Remote C operating modes, which are explained under the “Custom ASCII Protocol
Transmitter Communications” section of this manual.
The
Control Inputs
pull-down menu controls the effect of grounding Control Input 1, Control Input
2, or both. Selections applicable to the serial input transmitter are the following:
•
Meter Reset, Function Reset, Meter Reset
(first row). When this row is selected, grounding
Control Input 2 (causes a function reset, which resets latched alarms.
•
Activate Alarm 1
,
Activate Alarm 2
,
Activate Alarm 1&2
. When this row is selected, grounding
Control Input 1 activates relay 1, grounding Control Input 2 activates relay 2, and grounding
both inputs activates Alarms 1 & 2.
•
Tare Enable, Tare if Enabled, Tare
(last row). When this row is selected, grounding Control Input
1 (normally with a permanent connection) enables the Tare function. Momentarily grounding
Control Input 2 stores the current digital value as an offset and subtracts this offset from the
digital reading sent to the transmitter, resulting in a zero value for alarms and the analog output.
This offset will also be subtracted from all new readings sent to the transmitter. To change the
offset, momentarily ground Control Input 2 for the new input.