Installation – Liquid Controls HMS501, HMS600, HMS1000, HMS2400, HMS2500, and HMS5000 LC Mag IOM User Manual

Page 7

Advertising
background image

7

Operating Pressure (PSI)

140

260

350

600

1000

Liner

PTFE

Ebon.

PTFE

Ebon.

PP

PTFE

Ebon.

PTFE

Ebon.

Ebon.

N.D
1"

25

19

25

25

1¼"

43

28

43

43

1½"

53

36

53

53

2"

68

52

68

68

2½"

90

75

45

45

3"

53

41

53

53

4"

59

56

83

83

5"

71

71

112

112

6"

108

106

135

135

8"

148

123

99

82

134

112

178

149

233

10"

123

103

140

117

204

170

267

223

321

12"

142

119

175

146

201

168

278

232

317

14"

172

143

205

171

324

270

422

352

481

16"

217

181

282

235

426

355

619

516

623

18"

194

161

281

234

20"

224

186

382

318

24"

323

269

568

474

Installation

Torque Specifications (Nm) for HMS1000 and HMS2500 Meters

Tighten bolts uniformly in diagonally opposite sequence.

The torques listed in the table are applicable to flanges: UNI 2223, DIN 2501, BS 4504, ANSI B16.5

The use of DIN 2690 gaskets is recommended.

Contact the manufacturer for nominal diameters greater than 24" .

Advertising