7
Operating Pressure (PSI)
140
260
350
600
1000
Liner
PTFE
Ebon.
PTFE
Ebon.
PP
PTFE
Ebon.
PTFE
Ebon.
Ebon.
N.D
1"
25
19
25
25
1¼"
43
28
43
43
1½"
53
36
53
53
2"
68
52
68
68
2½"
90
75
45
45
3"
53
41
53
53
4"
59
56
83
83
5"
71
71
112
112
6"
108
106
135
135
8"
148
123
99
82
134
112
178
149
233
10"
123
103
140
117
204
170
267
223
321
12"
142
119
175
146
201
168
278
232
317
14"
172
143
205
171
324
270
422
352
481
16"
217
181
282
235
426
355
619
516
623
18"
194
161
281
234
20"
224
186
382
318
24"
323
269
568
474
Installation
Torque Specifications (Nm) for HMS1000 and HMS2500 Meters
•
Tighten bolts uniformly in diagonally opposite sequence.
•
The torques listed in the table are applicable to flanges: UNI 2223, DIN 2501, BS 4504, ANSI B16.5
•
The use of DIN 2690 gaskets is recommended.
•
Contact the manufacturer for nominal diameters greater than 24" .