Servicing the drive components the retaining plate – Liquid Controls MS Meters User Manual

Page 20

Advertising
background image

20

Servicing the Drive Components

The Retaining Plate

The retaining plate has four holes”

Two that are drilled 1.5” on center
Two that are drilled 1.625” on center.

Turn the retaining plate until the holes match up with the
threads to determine which orientation is correct for the
meter being serviced.

1.

Housing

2.

Drive Blade

3.

Bushing

4.

Shaft

5.

Retaining Clip

6.

“U” Cup

7.

Rulon Thrust Washer

8.

Stainless Steel Thrust Washer

9.

Nylon Washer

10.

O-Ring

11.

Retaining Plate

12.

Retaining Plate Screws (2)

13.

Roll Pin

14.

Output Gear 1:2

15.

Output Gear 1:1

1.

Housing

2.

Drive Blade

3.

Bushing

4.

Shaft

5.

Retaining Clip

6.

“U” Cup

9.

Stainless Steel Washer

10.

O-Ring

11.

Retaining Plate

12.

Retaining Plate Screws (2)

13.

Roll Pin

14.

Output Gear 1:2

15.

Output Gear 1:1

16.

Carbon Guide Bearing

Standard Packing Gland

LPG Packing Gland

Advertising