Continuous Injection System (CIS) Cleaning Procedure

Follow the steps below to circulate the cleaning mixture through the CIS fuel distributor to clean the
pressure regulator and the top portion of the fuel distributor.

1.

Verify

that

CIS Setup Steps 1-11

above have been completed before continuing.

2.

Refer to the vehicle's service manual for the manufacturer's recommended PSI.

3.

Adjust

Time

knob for 10 minutes.

4.

Press and hold the

Start/Run

switch.


5.

Turn

the

Pressure Adjust

regulator clockwise until the gauge displays

4 PSI.

The pump will

remain on.

6.

Release

the

Start/Run switch and continue to turn the Pressure Adjust regulator clockwise until

it is completely closed. This will clean the CIS fuel distributor and filter particles through the LE-
1’s filtering system.

Check all connections for leaks.

• Make a note of the fuel pressure reading; this is the true opening pressure of the vehicle's

pressure regulator when the engine is at normal operating temperature.

NOTE:

By turning the

Pressure Adjust

regulator in and out

PULSING

the mixture from

time to time, the cleaning process will be enhanced in this mode.

• If the

“PULSING”

is too great, it could stop the engine.

7.

After the 10 minutes has expired,

adjust time for 30 minutes. (Run time may be adjusted

depending on the condition of the vehicle’s fuel system.)

8.

Press

the

Start/Run

switch.


9.

Start the vehicle

to begin the fuel system cleaning process.

• When the cleaning process is halfway completed, step on the vehicle’s accelerator quickly

three or four times.

Then,

maintain RPM at 1500 - 2000 for 30 seconds.


• If the vehicle is equipped with a

Cold Start Injector

, you may use a

Pulse Tester

to energize

the

Cold Start Injector

a few quick times during the run cycle to clean it.

10.

When the run time expires, the cleaning is complete. The unit will automatically shut off and the
LE-1’s alarm will sound.