12 i 12 j – Dixon Valve 100 TON RAM SEC05 External Swaged Cam and Groove User Manual

Page 9

Advertising
background image

Cam & Groove Holedall Couplings

customer service

800

355

1991

7

Section 5

100 Ton Ram Instruction Manual

12i

12j

Position a rubber sheet or pad under the die bed.
While holding the die in place with one hand, loosen
the bolt on the tie down bar and move the tie down
bar so that it clears the die.

Slowly slide the hose

towards the pusher. When the die clears the die
holder, one or both halves may fall to the floor. If
one half remains on the ferrule, tap it with a mallet
until it releases. If both halves remain on the ferrule,
it may require the halves be pried apart at the seam.

Remove the spacer rings from the coupling. Wipe
off excess lubricant from hose and ferrule. Bring the
hose with stem and ferrule back through the die bed.
Reinstall the gasket. Close the cam arms.

Note: Remove spacer ring from the 1-1/2" size only.