1 b 1 a 2 – Dixon Valve 100 TON RAM SEC03 External Swage Holedall with Jackscrews User Manual

Page 3

Advertising
background image

1-1/4" through 4" Standard & Long Flanged Holedall Swaged Couplings using Collar with Jack Screws

customer service

800

355

1991

1

Section 3

100 Ton Ram Instruction Manual

Install the 4" main pusher (M011-065) by sliding it
onto the rod cap of the ram cylinder. Make sure that
the pusher is all the way on the rod cap.

For 1-1/4" - 3" couplings proceed to

Step 1b.

For 4" couplings, proceed to

Step 2.

For 1-1/4" - 3" couplings insert the appropriate size
adapter pusher into the 4" main pusher (

M011-065

).

For example:
Shown here is the 2" adapter pusher (M011-113)
being inserted.

1b

1a

2

Any coupling assembly (welding of stem, stub end, flange, etc.) must be done prior to

starting this procedure. Failure to do so (i.e. welding flange to stem after the swage)

can result in serious structural damage to the hose and premature assembly failure.

Accurately measure the hose O.D. with a diameter
tape. Each end of the hose should be measured to
guarantee the correct ferrule and die selection.
Select the correct ferrule and die based upon the
hose free O.D. just measured from the die chart.

Advertising