Dixon Valve 100 TON RAM SEC01 Specifications User Manual

Page 4

Advertising
background image

100 Ton Ram Instruction Manual

Specifications

2

Section 1

Specifications:

Net Weight

1,900 lbs., basic equipment only

Crated Weight

2,100 lbs.

Dimensions

60" long x 26" wide x 48" high

Crated Dimension

76" long x 40" wide x 48" high

Pump Motor

Power Team PE554 1-1/8 H.P. Universal Motor;
12,000 RPM; 115V single phase, 60/50 cycle AC (not dual voltage);
25 Amp, lightweight “handle-top” housing

Motor Control

“Run-Off-Remote” motor control switch; 25 Amp motor control relay
Cavity mounted in motor housing, hand held remote switch

Safety Valves

Relief valve set at 10,000 PSI

Control Valve

Built-in manually operated 4-way control valves with 3/8" NPT port

Gauge

Calibrated 0-10,000 PSI

Reservoir

Convenient mounting holes in base

Oil Delivery

650 cu. in/min. at 100 PSI
80 cu. in/min. at 1,000 PSI
70 cu. in/min. at 5,000 PSI
55 cu. in/min. at 10,000 PSI

Note:

2-stage pump provides fast, no load approach speed and then shifts into slow actuation
as the load is applied.

• Ram double acting (Power Team RD10013)
• 13-1/8" stroke
• 103.1 tons of push at 10,000 PSI
• 44.2 tons of pull at 10,000 PSI

Preparations:

Filling the Reservoir

Before removing the filler plug, clean the area around the plug.
The pump is a precision built unit, so special care should be taken to preclude
foreign particles from entering the reservoir. With cylinder fully retracted, fill the
tank 1" to 1½" from the top. Replace the filler plug.

Approved Hydraulic

Power Team 9637 Mobile DTE25 or equivalent.

Oils

Available Motor

220-440, etc. Also 1½ H.P. and 3 H.P.

Variations

Reservoir

5 gallon or 10 gallon reservoir available

Variations

The standard 1-1/8 H.P., 12,000 RPM, 115 volt motor and the 2½ gallon reservoir has proven highly successful.
Dixon feels it is the best design, and variations are not desirable.

Advertising