0 introduction – Nova-Tech LMI Roytronic Excel Series AD Metering Pump User Manual
Page 6
6
INTRODUCTION
2.0 Introduction
LMI is the world’s most versatile manufacturer of economical and efficient metering
pumps. This manual addresses the installation, maintenance and troubleshooting proce-
dures for manually and externally controlled pumps. LMI has a worldwide network of
stocking representatives and authorized repair centers to give you prompt and efficient
service.
Please review this manual carefully. Pay particular attention to warnings and precautions.
Always follow good safety procedures, including the use of proper clothing, eye and face
protection.
2.1 Specifications
AD2XY
(where X is any number;
where Y is 1, or 8)
AD2XY
(where X is any number;
where Y is 2,3,4,5,6,7, or 9)
AD8XY, or AD9XY
(where X is any number;
where Y is any number)
Operating
Temperature
14 to 113°F
–10 to 45°C
14 to 113°F
–10 to 45°C
14 to 113°F
–10 to 45°C
Voltage
110 to 120 V
220 to 240 V
95 to 240 V
Frequency
50 to 60 Hz
50 to 60 Hz
50 to 60 Hz
Max. Current
2.0 A
1.0 A
1.4 A
Wattage
25 W
22 W
20 W
AD2
AD8
AD9
Battery
N/A
N/A
Panasonic BR1225 or
Renata CR1225 or
Energizer/Eveready
CR1220
Fuse
Bel Fuse 5HT1.25-R
Time-lag, 5mm x 20mm
Bel Fuse 5HT 2-R
Time-lag, 5mm x 20mm
Bel Fuse 5H 2-R
Time-lag, 5mm x 20mm
* The battery and fuse are internal, factory serviceable parts, and must be replaced by the factory or a qualified
distributor with parts of the same type and rating.