51
RELAY 1
(DOOR 1) OPEN
INTERVAL
(01-90 seconds)
Step 1
Entering The Programming
Mode: Press 0 and # simultaneously
then release. If you are in the
programming mode, proceed to step 2.
Step 2
Enter the 4-digit Master
Code (factory default is 0000) and you
will hear “One Short Beep”. If you
entered an invalid master code you will
hear “One Long Beep”, repeat
step 1. Should your master code
become lost or forgotten see Reset
Master Code.
Step 3
Enter the Index Number
(01 – 50) where you stored the access
code to be deleted.
• “Two Long Beeps” if the Index
Number has an associated access
code, proceed to step 4.
• “No Beep” if the Index Number has
no associated access code and
press “
∗” and repeat this step.
Step 4
Enter
• 0 then # to delete the access code,
you will hear “One Short Beep” or
• 1 then #, you will hear “No Beep”
and enter the new access code and
you will hear “One Short Beep”.
Step 5
Return to step 3 to delete
another access code or enter another
Function Code to program another
parameter, otherwise press
∗ to exit
and you will hear “Three Short
Beeps”.
Step 1
Entering The Programming
Mode: Press 0 and # simultaneously
then release. If you are in the
programming mode, proceed to step 2.
Step 2
Enter the 4-digit Master
Code (factory default is 0000) and you
will hear “One Short Beep”. If you
entered an invalid master code you will
hear “One Long Beep”, repeat
step 1. Should your master code
become lost or forgotten see Reset
Master Code.
Step 3
Enter 51 then #, you will
hear “One Short Beep”.
Step 4
Enter door 1 open interval
value (01 – 90 seconds) then press #,
you will hear “One Short Beep”.
Step 5
Enter another Function Code
to program another parameter
hear “Three Short Beeps”.
Must delete the individual access
code from the local keypad.
Pick up the phone and wait for a dial
tone.
Step 2
Press # # and you will hear
“One Short Beep”.
Step 3
Press # and you will hear
“One Short Beep”.
Step 4
Enter the Function Code 51
then press #, you will hear “One Short
Beep”.
Step 5
Enter door open interval
(01 – 90 seconds) then press #, you
will hear “One Short Beep”.
Step 6
Enter another function code
to program a different parameter or
exit the program by pressing
∗ ∗ and
you will hear “Three
Short Beeps”.
Must delete the individual access
code from the local keypad.
Step 1
Call to the AeGIS 400RTP
system (you must know the system’s
phone number), you will hear: “One
Short Beep”, the gate is locked. “Two
Short Beeps”, the gate is unlocked.
Step 2
Press # then enter a valid
master code and you will hear:
• “One Short Beep”, the master code
is accepted then press # and you will
hear “One Short Beep”.
• “One Long Beep”, the master code
is rejected and the connection will be
disconnected.
Step 3
Enter the Function Code 51
then press #, you will hear “One Short
Beep”.
Step 4
Enter door open interval
(01 – 90 seconds) then press #, you
will hear “One Short Beep”.
Step 5
Enter another function
code
to program a different parameter or
exit the program by pressing
∗ ∗ and
you will hear “Three Short Beeps”.
Pach and Company
Page 10
AeGIS 400RTP
Chapter 3. Programming
Delete or
overwrite
Individual
Access Code
Function
Local Programming
Premise Phone
Remote Phone