2 wiring diagram 8.3 continuity diagram, Key switch – Ariens 513-517 User Manual

Page 39

Advertising
background image

8 - 39

8.1 BATTERY (ELECTRIC START MODELS)

IMPORTANT: Use battery charger supplied only. DO
NOT attempt to "jump start" mower.

To charge with battery charger, connect charger plug to
mating plug on battery (not engine) and plug charger
into 110 volt Alternating Current (A.C.) outlet. Charge
for 24 to 48 hours (battery may be charged for up to 72
hours with no harmful effects).

An engine run time of at least 8 hours is required to
charge a fully discharged battery.

To Remove Battery from Unit

1. Remove wing nuts from battery U-bolt.

2. Disconnect battery from wiring.

8.2 WIRING DIAGRAM

8.3 CONTINUITY DIAGRAM

SECTION 8 - ELECTRICAL

S

B

A

M

R

RED

BLA

CK

BATTERY

1

2

3

4

A

B

KEY SWITCH

RED

BLACK

RED

RED

RED

RED

YELLOW

WHITE

BLACK

GREEN

ENGINE

1

2

3

4

PM0090

Key Switch

(01155800)

OFF

S

B

A

M

R

RUN

S

B

A

M

R

START

S

B

A

M

R

The diagram below shows the various states of connection for electrical components.
The solid lines on switches show continuity.
NOTE: All switches are viewed from the rear.

PM0100

Advertising
This manual is related to the following products: