C. DRYER ENCLOSURE REQUIREMENTS

Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of

12-inches (18-inches or more is recommended for ease of installation, maintenance , and service) above the

dryer outer top, except along the front of the dryer which may be partially closed in if desired. The clearance

between the bulkhead header and the dryer must be a minimum of four (4) inches and must not extend more

than four (4) inches to the rear of the front. The bulkhead facing must not be closed in all the way to the top of

the dryer. A one (1) inch clearance is required.

NOTE: Allowances must be made for opening the control door.

Dryers may be positioned side wall to side wall. However, a 1/16" minimum allowance must be made for

opening and closing of the control door and the lint door. It is suggested that the dryer be positioned about two

(2) feet away from the nearest obstruction for ease of installation, maintenance, and service (to be measured

from the back guard.) (Refer to the illustration above for details.)

NOTE: Air considerations are important for proper and efficient operation.

IMPORTANT: Even though a minimum of only 12-inches is required, 18-inches or more is

suggested. The additional clearance is advantageous for ease of installation and

service.

IMPORTANT: When fire sprinkler systems are located above the dryers, a minimum of

18-inches above the dryer console (module) is required. Dryers may be

positioned side wall to side wall however, a 1/16-inch minimum allowance is

required between dryers (or wall) for ease of installation and maintenance.

Allowances must be made for the opening and closings of the control door and

the lint door.