Specifications and operating features – Electronics International US-8A User Manual
Page 35
SPECIFICATIONS and OPERATING FEATURES
31
Differential Limit: Programmable in 1F increments from 1F to 1999F from the front panel. One limit for each
display.
Shock-Cooling: Programmable from 1 to 9 Seconds/F. One limit for each display.
Temp Prob Warning Lights: Lights for the following conditions:
A. Any channel over the High Limit. Also exhibits a high bar in the display.
B. Any channel under the Low Limit (in the scan mode only). Also exhibits a low bar in the display.
C. Any time the difference between the hottest and coldest analyzer channel exceeds the differential limit
(in the scan mode only). Also flashes a high and low bar in the display.
D. Blinks the Temp Prob light any time the displayed channel cools faster than the Shock-Cooling limit (in
normal mode only, not scan mode). This problem is only displayed for channels with a High Limit pro-
grammed between 300F to 600F and displaying a temperature between 300F and 600F.