Chapter 9: Troubleshooting

Page 9-8

9.6

Servo Amplifier Response / Resolver

9.6.1 Code 5-0

SERVO

AMPLIFIER REPLY ERROR / NO REPLY FROM RESOLVER

The controller is attempting to turn the motor but is not receiving any signals back from the
resolver to indicate that the tool is actually turning.

This abnormal is caused from;

1. The tool cable is damaged or not connected.

2. When the resolver, motor or the controller malfunctions.
3. If there is excessive binding in the fastener, transmission or the spindle assembly keeping

the motor from turning.

RECOVERY:

1. Verify that the tool cable is connected and not damaged.

2. Connect a spare tool cables to the existing tool.
3. Exchange tool and/or controller with known working units. Reinitialize the system after

exchanges.

4. Inspect and correct any binding in the spindle assembly, transmission or fasteners.