• Communication Range: >33 ft. (10m)

• Auto Power Off Interval: 15 minutes

• Backlight Fadeout Interval: 90 seconds

• Power Source: (1) “9V” battery

• Power Consumption: <3mA (standby mode);

<20mA (normal operating mode); <25mA (transmitting mode);
<60mA (receiving mode); <80mA (transmit + receive mode)

• Dimensions (Excluding Test Leads):

7.1 x 3.7 x 2.1 in. (180 x 95 x 54mm)

• Weight (Excluding Battery): 1 lb. (450g)

MEASUREMENT RANGES,
RESOLUTIONS & ACCURACIES

AC Voltage (Manual Range)

Range

Resolution

Accuracy

0-400mV

0.1mV

±0.6% of reading ±3 digits

0-4V

0.001V

±0.6% of reading ±3 digits

0-40V

0.01V

±0.6% of reading ±3 digits

0-400V

0.1V

±0.6% of reading ±3 digits

0-750V

1V

±1.0% of reading ±5 digits

DC Voltage (Manual Range)

Range

Resolution

Accuracy

0-400mV

0.1mV

±0.6% of reading ±2 digits

0-4V

0.001V

±0.6% of reading ±2 digits

0-40V

0.01V

±0.6% of reading ±2 digits

0-400V

0.1V

±0.6% of reading ±2 digits

0-1000V

1V

±0.8% of reading ±2 digits

AC Current (uA Setting, Manual Range)

Range

Resolution

Accuracy

0-400uA

0.1uA

±0.15% of reading ±5 digits

0-4mA

1uA

±0.15% of reading ±5 digits