Operating the PV Solar Input
The battery box is comes with a solar input port and a DC to DC controller that provides
an alternative method to charge the internal battery. A solar charge indicator located at
the back of the battery box to indicate the charging status of the internal battery.
The DC to DC controller is a fully automatic self-sustaining device that will initiate the
charge cycle when solar power is available. Please note that the DC to DC controller is
designed to be used with the provided KISAE 80W solar panel. Connected to other
solar panel may damage the unit or over

charge the battery. If insufficient charge

capacity is not available from the solar source, it is recommended to use the internal 5A
charger to complete the battery charging process through the utility.

priority
In2,Ch0,
Al1

amber

Output Power
“X.XX” in kW &
battery
capacity “XX”
in %

through internal battery and/or solar power

Solid
green

“XX” in (%)

AC output is supplied by utility AC power

Display shows battery capacity

Solid red

“E01-E11”

Error on unit is detected. AC output is
disconnected. See Trouble Shooting
section.

Backup
priority
with alarm
disable
In2,Ch0,Al
0

Same as “Backup Priority mode” but with audio alarm disabled. The unit
fault protection features remain active and will shut down without audio
warning when fault occurs.

Backup
disable
In0,Ch1,
Al1

Solid
green

“Ful”

AC output is supplied by utility AC power

Internal battery is fully charged

Flashing
green

Flash between
“Chg” & “XX”
battery
capacity in %

AC output is supplied by utility AC power

Charging of internal battery by 5A charger
is in progress

Backup
disable
with alarm
disable
In0,Ch1,
Al0

Same as “Backup disable mode” but with audio alarm disabled. The unit
fault protection features remain active and will shut down without audio
warning when fault occurs.

Backup
and
charger
disable
In0,Ch0,Al
0or Al1

Solid
green

“Ful”

AC output is supplied by utility AC power
and battery is full charge

Green

“XX” in (%)

AC output is supplied by utility AC power
and display shows battery capacity