AdaptaFlow Node Adapter - Installation

An 82 ohm resistor is provided on the Interface Board to terminate the RIO cable. Where the RIO cable
is daisy-chained to more than one Node Adapter, only the last connection point in the daisy-chain should
be terminated by moving the associated switch to the “TERM” position.