3 precautions 4 installation/wiring/setup, 1installation, 2wiring – Securitron WSS User Manual

Page 2

Advertising
background image

3 Precautions

4 Installation/Wiring/Setup

☐ Shut off power to power source before attempting any wiring procedures.
☐ Maintain a clean and safe environment when working in public areas.

unexpected reactions by the door.

☐ Observe proper protocols for circuit board handling to protect the unit from electrostatic discharge.

Before handling any board ensure you dissipate your body’s charge.

☐ Check placement of all wiring before powering to ensure that moving door parts do not

catch wires and cause damage to equipment.

☐ Ensure compliance with all applicable safety standards (i.e. ANSI A156.10/A156.19) upon

completion of installation.

☐ DO NOT attempt any repair of the sensor. Unauthorized disassembly or repair:

1. May jeopardize personal safety and may expose one to the risk of electrical shock.

2. Will void the product warranty.

1

Installation

Mounting

Ring

Gang

Box

or

WSS

Assembly

Mounting

Ring

Gang

Box

or

WSS

Assembly

Adapter Ring

Foam Gasket

1. The WSS may be mounted using the included mounting

ring or in a standard plastic or metal electrical gang

boxes. Do not allow contact between the sensor and

a metal gang box to prevent shorting the devices. Be

sure to place the device so that motion from the door

or other types of movement do not interfere with the

detection zone.

2. Depending on the door installation, the weather resistant

foam gasket or the plastic adapter ring may be used.

The weather resistant foam is used as a protective

barrier against the elements. The plastic adapter ring is

designed to enable the double gang face plate to attach

to various plastic and metal gang boxes.

2

Wiring

PWR: Black - 12 to 24 VAC/VDC: -5% to +10%

PWR: Red - 12 to 24 VAC/VDC: -5% to +10%

NC: Empty - NC Contact

NO: Green - NO Contact

COM: White - Common at Door Control

W

S

S

C

O

N

T

R

O

L

NC NO COM POWER

NC NO COM POWER

B

lack - 12

to

24

V

A

C / VD

C

Red - 12 to

24

V

AC / VD

C

White - Com a

t

Door Control

Green - NO Cotact

Empty - NC

Conta

ct

1. Wire the 4-conductor cable as shown above.

2. Attach the 4-conductor cable connector to the WSS

as shown.

500-23700_A

Advertising