3.4. EFFICIENCY

3.4.1 General

Under the load conditions defined in Table 1. and Table 2. The loading condition for

testing efficiency shown in Table 1 represents a fully loaded system. ~ 50% (typical)

loaded system. and ~ 20% (light) loaded system.

Table 1. Loading Table for Efficiency

Measurements

300W(loading shown in Amps)

Loading +12V

+5V +3.3V -12V +5Vsb

Full 18.7

7.58

7.96 0.31 1.56

Typical 9.3

3.79

3.98 0.16 0.78

Light 3.7

1.52

1.59 0.06 0.31

Table 2. Minimum Efficiency Vs Load

Loading Voltage Full load Typical load Light load

Required Minimum Efficiency 115V >82% >85% >82%

Required Minimum Efficiency 230V >85%

>87%

>85%

Minimum Efficiency for test purposes are considered to be within ±1.0% of nominal.

3.4.2 Standby Power Consumption (+5Vsb):

Input Power < 0.5W @+ 5Vsb/45mA & 230Vac input

PS_ON input signal @ High State