Table 7-1
Troubleshooting Guide
Symptom Cause
Remedy
Contactor contacts
arcing
Check for burned contacts. Replace as needed.
Loose connection in
circuit
Check all wires and terminals for bad connections. Replace as
needed.
Hoist and/or Trolley
operates intermittently
Broken conductor in
Pendant Cord
Check for intermittent continuity in each conductor of the Pendant
Cord. Replace entire Pendant Cord if continuity is not constant.
Trolley making loud
noise.
Trolley wheel
maladjusted on beam
Readjust the gap between the trolley wheel flange and the beam
flange.
Trolley will not move
Trolley wheel spacing
on beam too tight
Readjust the gap between the trolley wheel flange and the beam
flange.
Abnormal noise from
wire rope and/or drum
Lack of lubrication,
worn wire
rope/drum/sheaves
Lubricate or replace wire rope/drum/sheaves