Heatsink dimensions & identification, Amps, Dc output ma to 2 amps – LEESON 15 Series - 174695.00 Hook-Up User Manual
Page 2: Input frequency 60 hertz, Input voltage, Vac or 240 vac, Output voltage, Overload capacity % for 1 minute, Speed control k ohm speed potentiometer, Speed range :1

HEATSINK DIMENSIONS & IDENTIFICATION
174694.00/174695.00 Rev.A MODEL SPECIFICATIONS
AC Input Voltage ............................................................... ................................. ± 10% Rated Line Voltage
Amps
-
DC Output ............................................................................................................ 150mA to 2 Amps
Dimensions ........................................ ............................... 174694.00: 2.80" wide, 1.30" high, 3.30" deep
Dimensions
.............................. ......................................... 174695.00: 2.80" wide, 1.50" high, 3.30" deep
Input Frequency ...................................................................................... ............................... 50160 Hertz
Input Voltage -
.................................................................. ........................................... 120 VAC or 240 VAC
I.R. Compensation .................................................................. ................................ Adjustable -full range
Max. Speed ...................................................... ............................... Adjustable (40 -120% of Base Speed)
Min. Speed ..................................................................... ................................ Adjustable (0 - 30% of Max)
Output Voltage
........................... ........................................................................................... 0-105 or 0-210 VDC
Overload Capacity ........................................................................... ............................... 200% for 1 minute
Shunt Field Voltage ................................................. ............................... 1 Amp max, 100 VDC at 120 VAC
Shunt Field Voltag
................................................... ............................... 1 Amp max, 200 VDC at 240 VAC
Speed Control .............................................................. ............................... 5K Ohm Speed Potentiometer
Speed Range ......................................................................................................................................... 25:1
Speed Regulation ....................................................................... ................................. ± 1% of Base Speed
Temperature Range .......................................... ............................... -10
0
to 45
0
C. Ambient (15
0
to 115
0
F.)
Transient Protection ..........................................................................................................................................G-Mov
Weight ................................................................... .............. ............................... 174694.00 weighs 2.64 oz.
Weight
................................................................................. ............................... 174695.00 weighs 3.03 oz.
With suitable external heatsink, current can be increased to 4 Amps. The control’s heatsink temperature
should not exceed 70° C. Equivalent to 4" x 4" x 0.125" thick aluminum plate mounted to housing.
.178
.318
.140
1 or 1A HOUSING"
.592
.203
.240
2.055
2 500 +/- 050
.216
1.261
C
L
.377 DIA.
(1 HOLE)
.140 DIA.
(2
PLACES)
.750
.230
(SIDE PROFILE)
2 or 2A HOUSING"
2.126
2.326
GRAFTON, WISCONSIN 53024-0241 U.S.A.
TEL. (262) 377-8810 FAX (262) 377-9025