Operation, Opera t orʼs manual, B. connect leads and cables on the machine – Lincoln Electric IMT10106 POWER MIG 180 DUAL User Manual

Page 13: C. load wire spool

Advertising
background image

B-5

OPERATION

B-5

POWER MIG® 180 DUAL

B. CONNECT LEADS AND CABLES ON

THE MACHINE

(See Figure B.7)

1. Open the case side door

2. Slide the connector end of the gun and cable

through the hole in the machine front and into the
gun connector bushing on the wire drive.

3. Make sure the gun connector end is seated fully

into the wire drive and tighten the thumbscrew to
secure the gun connector.

4. Plug the gun trigger lead connector into the 4 pin

gun trigger receptacle on the machine front.

5. Wire Drive Polarity. Flux cored welding requires

negative (-) polarity. Connect the short power
cable from the wire drive to the negative (-) output
terminal and tighten the Wing Nut.

6. Work Lead Connection. Slide the lugged end of

the work cable through the hole in the machine
front and place on the positive (+) output terminal
and tighten Wing Nut.

C. LOAD WIRE SPOOL

(See Figure B.8)

1. Locate the 4"(102mm) diameter spool of

.035”(0.9mm) NR-211MP flux-cored wire and
place onto wire spool spindle. Orient the spool so
that the wire feeds off the top of the spool.

2. Secure spool in place by tightening the wing nut

against the against the spacer that holds the wire
spool on the spindle.

3. Open the top drive roll pressure arm by rotating

the tension adjustor arm down and pivoting the
drive roll pressure arm up.

4. Remove the outer wire guide.

4a. Slide gun out of drive slightly.

5. Remove the lower drive roll and inner wire guide.

6. Install the .025”-.035”(0.6mm-0.9mm) inner wire guide.

7. Install the .030”/.045”(0.8mm/1.1mm) knurled lower drive

roll.

8. Carefully unwind and straighten the first six inches of

welding wire from the spool. Do not let the end of the
wire go to prevent the wire from unspooling.

GUN AND CABLE

WORK CLAMP

(4 PIN)
LEAD CONNECTOR

TERMINAL END
(FITS ON STUD INSIDE
SEE FIGURE BELOW)

SLIDE
CONNECTOR
END HERE

CASE SIDE DOOR

OPEN LATCH DOOR

WORK CLAMP

(4 PIN)
TRIGGER RECEPTACLE
PLUGGED IN

CONNECTOR
END ATTACH

ALL COMPONENTS SHOWN CONNECTED
(FRONT AND SIDE DOOR IS REMOVED
FOR CLARITY)

SHORT POWER
CABLE NEGATIVE "-"
OUTPUT TERMINAL

WORK LEAD
CONNECTION
POSITIVE "+"
OUTPUT TERMINAL

THUMB SCREW TO
TIGHTEN CONNECTOR
BUSHING

LOCATE COMPONENTS
TO CONNECT TO THE
FRONT OF MACHINE

FIGURE B.7

WIRE SPOOL
.035" (0.9mm)

NR-211-MP

INNER WIRE GUIDE REMOVED

LOWER DRIVE ROLL REMOVED

OUTER WIRE
GUIDE REMOVED

TOP DRIVE ROLL PRESSURE ARM

TENSION ADJUSTOR DOWN

FIGURE B.8

OPERA

T

ORʼS MANUAL

Advertising