Installation, Select suitable location, Safety precautions – Lincoln Electric IMT10135 WIRE FEEDER WELDER 180 User Manual

Page 7: Warning

Advertising
background image

A-1

A-1

INSTALLATION

WIRE FEEDER WELDER (180 MODEL)

OPERA

T

OR

ʼS

 MANUAL

TECHNICAL SPECIFICATIONS 180 Amp units (K2481-1, K2515-1, K2659-1, K2698-1)

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

Standard Voltage/Frequency

Input Current

230 V 60 Hz

20 Amps @ rated output

208 V 60 Hz

20 Amps @ rated output

Voltage/Duty Cycle

Current

Voltage at Rated Amperes

230 V 30%

130 Amps

20

208 V 30%

130 Amps

17.6

Welding Current Range

Open Circuit Voltage

Wire Speed Range

30-180 Amps

34 V

50 - 500 in/min.

(1.3 - 12.7 m/min.)

Input Voltage/Frequency Fuse or Breaker Size

1

Input Amps Minimum Input Cable

230/208 V 60 Hz 40 Amp Super Lag

20 14 AWG

RECOMMENDED INPUT CABLE AND FUSE SIZES

Height

Width

Depth

Weight

13.7 in

10.15 in

18.2 in

56 Ibs

347 mm

258 mm

462 mm

25.4 kg

PHYSICAL DIMENSIONS

1

If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.

SELECT SUITABLE LOCATION

Locate the welder in a dry location where there is free
circulation of clean air into the louvers in the back and
out the front of the unit. A location that minimizes the
amount of smoke and dirt drawn into the rear louvers
reduces the chance of dirt accumulation that can
block air passages and cause overheating.

STACKING

WIRE FEEDER WELDER(180 MODEL) cannot be
stacked.

TILTING

Each machine must be placed on a secure, level sur-
face, directly or on recommended cart. The machine
may topple over if this procedure is not followed.

Read entire installation section before starting
installation.

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

• Only qualified personnel should

perform this installation.

• Only personnel that have read and

understood the WIRE FEEDER

WELDER Operating Manual should

install and operate this equipment.

• Machine must be plugged into a receptacle

which is grounded per any national, local or

other applicable electrical codes.

• The WIRE FEEDER WELDER power switch is

to be in the OFF (“O”) position when installing

work cable and gun and when connecting

power cord to input power.

---------------------------------------------------------------------

WARNING

Advertising