Watlow DIN-A-MITE Style C User Manual

Page 6

Advertising
background image

142 mm (5.59 in)

131 mm

(5.17 in)

146 mm (5.74 in)

102 mm (4.0 in)

Front panel is touch-safe,
no clearance is required.

102 mm (4.0 in) clearance for air flow and wire bending radius

102 mm (4.0 in) clearance for air flow and wire bending radius

150 mm

(5.89 in)

44 mm

(1.73 in)

57 mm

(2.26 in)

127 mm

(5.00 in)

79 mm

(3.10 in)

102 mm (4.0 in) minimum

Side

Rail Release Tab
(pull down)

194.1 mm

(7.64 in)

1. Push the unit in and down to catch the rail

hook on top of the rail.

2. Rotate the bottom of the unit in toward the

rail.

3. The rail clasp will audibly “snap” into place.

If the DIN-A-MITE does not snap into place,
check to see if the rail is bent.

4. Mount the cooling fins vertically.

ç

3

WARNING:
Only authorized and
qualified personnel
should be allowed to
install and perform
preventive and corrective
maintenance on this unit.
Failure to follow this
guideline could result in
damage to equipment,
and personal injury or
death.

5

WARNING:
Hot surface, do not touch
the heat sink. Failure to
follow this guideline could
result in personal injury.

ç

Mount the cooling fins
vertically.

Unit Dimensions - Fan-Cooled

з
У

3

5

1

1

2

Mount

Dismount

6

WATLOW DIN-A-MITE Style C User's Manual

1. Press down on the release tab while rotating

the unit up and away from the rail.

3

4

Advertising