15 diagnostics – Hired-Hand Evolution 4000 Control System User Manual

Page 47

Advertising
background image

Part No. 4801-5338 Rev 01-10

Evolution 4000

47 of 86

**DIAGNOSTICS**

"

For Qualified Technician Use Only:
(1)Power Ventilation Auxilary SWX:

(2)Ignore Inlet #1 Auxiliary SWX = Yes
(3)Ignore Inlet #2 Auxiliary Swx = Yes

(4)Natural Ventilation Auxiliary SWX:

(5)Ignore Unit #1 Auxiliary SWX = Yes
(6)Ignore Unit #2 Auxiliary Swx = Yes
(7)Ignore Unit #3 Auxiliary Swx = Yes
(8)Ignore Unit #4 Auxiliary Swx = Yes

(9)Feed Level Sensor:

(10)Maximum Range = 26.00 ft

(11)Dead Zone = 1.50 ft

(12)Soft Resets = 0
(13)Voltage Resets = 0
(14)Hard Resets = 0

(15)
Temp 1:

255

Outside:

255

Temp 2:

255

Humidity 1:

0

Temp 3:

255

Humidity 2:

0

Temp 4:

255

Feed 1:

0

Temp 5:

255

Feed 2:

0

Temp 6:

255

GP 1:

0

Temp 7:

255

Temp 8

255

Vent Opened:

No

Water 1:

Yes

Tunnel Closed:

No

Water 2:

Yes

Curt 1 Closed:

No

Run 1:

Off

Curt 2 Closed:

No

Run 2:

Off

Curt 3 Closed:

No

Curt 4 Closed:

No

**Password Setup**


Enter a new password for this
controller and press ENTER:

New Password: 0000

(1) Seasonal Programs – Select Program 0, 1 or 2 for the current operating program.

This selection can also be used to COPY FROM the Seasonal Program number to the selected program
number shown in the item 3 below.

(2) Program Name – The program name can be changed to include a special title, letters, numbers, and

characters up to 8 digits in length.

(3) Copy to Program – Enter the COPY TO program number (0, 1, or 2).
(4) Enter to Proceed – When “Enter to Proceed” is selected and the ENTER button is pressed, the Copy to

Program number programming contents is replaced with the programming contents of the Seasonal
Program number.
NOTE: This action is not reversible.

(5) Change Password – Select “Change Password” for

changing the existing password for the Controller. The
four digits will allow a numeric password from 0001 to
9999. Changing the Password to 0000 disables the
locks until the password is changed to a number
between 0001 and 9999.
NOTE: Record the password in a convenient retrievable location.

7.15 Diagnostics

The Diagnostics screen is for qualified
technician use only and can only be changed
by using the service code. Contact the local
dealer for assistance.
(1) Power Ventilation Auxiliary SWX -

Setting these options to Yes will ignore
the indication from the curtain switch.
This feature will totally ignore the
auxiliary switches on the PT machines
when answered yes.

Note: This must be answered 'No' and the

open auxiliary switch of the vent
machine must be connected in order
to use the feature of running the
tunnel curtain with the vents during
Power ventilation when the pressure
is to high and the vents are
completely open.

(2) Ignore Inlet #1 Auxiliary Switch -

Yes or No

(3) Ignore Inlet #2 Auxiliary Switch -

Yes or No

(4) Ignore Inlet #3 Auxiliary Switch -

Yes or No

(5) Ignore Inlet #4 Auxiliary Switch -

Yes or No

(6) Natural Ventilation Auxiliary SWX -

Setting these options to Yes will ignore
the indication from the curtain switch.
This feature will totally ignore the auxiliary switches on the PT machines when answered "Yes".

Note: The auxiliary switches must be connected and this answered to no in order for the control to enter

into natural ventilation.

(7) Ignore Unit #1 Auxiliary Switch - Yes or No
(8) Ignore Unit #2 Auxiliary Switch - Yes or No
(9) Feed Level Sensor – Settings for setting the maximum range and calibration of the feed level sensor.
(10) Maximum Range - Total sensing range of the sensor.
(11) Dead Zone - Distance from the top of the feed bin to the bottom of the sensor.