Installation, Analog control cable, Control cable connections – Lincoln Electric IM872 LF-74 WIRE FEEDER User Manual

Page 14

Advertising
background image

A-6

INSTALLATION

LF-74

A-6

ANALOG CONTROL CABLE

CONTROL CABLE CONNECTIONS

K1797-xx
The control cable connecting the wire feeder to the
power source is specially made for the welding envi-
ronment.

The wire feeder power requires overcurrent protec-
tion. Connect the wire feeder only to power sources
with overcurrent protection of no more than 15 amps.

PIN

FUNCTION

LEAD#

A

Reserved

-------

B

Reserved

-------

C

Welding Output Control

2

(trigger from feeder)

D

Welding Output Control

4

(trigger from feeder)

E

Remote Voltage Control

77

(“+” supply from feeder or remote)

F

Remote Voltage Control

76

(control signal from feeder or remote)

G

Remote Voltage Control

75

(“-” supply from feeder or remote)

H

Reserved

I

42 VAC

41

J

Reserved

K

42 VAC

42

L

Reserved

M

Reserved

-------

N

Electrode voltage from feeder

67

Do not use more than 100 ft (30.5 m) of control cable
between the wire feeder and power source.

A

B

C

D

I

E

F

G

H

J

K

L

M

N

A

I

H

G

B

F

E

D

C

J

K

N

M

L

WIRE FEEDER

POWER SOURCE