Operation, Wire feed speed knob, Wfs calibration with digital meters – Lincoln Electric IM960 RED-D-ARC LN-25 PRO EXTREME User Manual

Page 19

Advertising
background image

3. WIRE FEED SPEED KNOB

The large, calibrated wire feed speed knob makes
for easy and accurate adjustment of the wire feed
speed. The knob rotates 3/4 turn. Turn the knob
clockwise to increase the wire feed speed, and
counter clockwise to reduce the wire feed speed.

The digital displays show the wire feed speed on
the display.

Wire Feed Speed, CV Operation

When Across the Arc models are operated with CV
power sources, the wire feed speed will remain a con-
stant value, independent of arc voltage changes, as
along as the arc voltage does not drop below the val-
ues per the following table:

CV Operation

Maximum WFS Minimum Arc Volts

280 15 V

340 17 V
440 21 V
520 24 V
600 27 V

B-4

OPERATION

B-4

RED-D-ARC LN-25™ PRO EXTREME

WIRE FEED SPEED UNITS

Rotate the WFS knob to
the left to use “inch-
es/minute”
for the wire
feed speed units.

Rotate the WFS knob to
the right to use
“meters/minute” for the
wire feed speed units.

Press the set-up button again.

US

A

O O

O O WFS

U o

r

E

A

O O

O O WFS

WFS CALIBRATION WITH DIGITAL
METERS

To calibrate the wire feed speed, before entering the
set-up menu:

Set the display to the desired wire feed speed (exam-
ple: 400 inches per minute)

Measure the actual wire feed speed (example: 405
inches per minute)

While in the set-up menu, adjust the calibration factor
as follows:

Actual WFS

405

Set WFS

400

Press the set-up button to exit the set-up menu.

=Calibration Factor Example

=1.01