Seed Hawk

®

Manual Calibration Guide

4

Meter Calibration & Procedures

NOTE: For convenient
calibration, your monitor is
able to be disconnected
from the tractor harness
and attached to your tank
harness.

Meter calibration is a

procedure that allows for

accurately setting the

individual meters to apply the

desired rate of material.

Before a meter calibration can be done the implement width

must be entered and the speed calibration must be completed

(See Sections 8.4.2 and 8.4.4 in your operator’s manual).




Canola

12 – 42

Inoculants 12 – 42
Flax

36 – 18

Canary


36 – 18

Wheat

36 – 18

Oats

36 – 18

Barley

36 – 18

Peas

36 – 18

Fertilizer

36 – 18

Fertilizer

36 – 18

Fertilizer

36 – 18

Ensure meter gates are fully open for proper product flow.

Low Range

12 – 42 gear ratio

High Range

36 – 18 gear ratio

Ensure that the high low range gears are correctly set
prior to calibrating each compartment.