Seed Hawk Ground Drive 2011 Calibration Guide User Manual
Page 5
Seed Hawk
®
Manual Calibration Guide
4
Meter Calibration & Procedures
NOTE: For convenient
calibration, your monitor is
able to be disconnected
from the tractor harness
and attached to your tank
harness.
Meter calibration is a
procedure that allows for
accurately setting the
individual meters to apply the
desired rate of material.
Before a meter calibration can be done the implement width
must be entered and the speed calibration must be completed
(See Sections 8.4.2 and 8.4.4 in your operator’s manual).
Canola
12 – 42
Inoculants 12 – 42
Flax
36 – 18
Canary
36 – 18
Wheat
36 – 18
Oats
36 – 18
Barley
36 – 18
Peas
36 – 18
Fertilizer
36 – 18
Fertilizer
36 – 18
Fertilizer
36 – 18
Ensure meter gates are fully open for proper product flow.
Low Range
12 – 42 gear ratio
High Range
36 – 18 gear ratio
Ensure that the high low range gears are correctly set
prior to calibrating each compartment.