Agitate liquid fertilizer, Liquid tank agitation procedure, 7 agitate liquid fertilizer – Seed Hawk Ground Drive: Granular & Liquid 2011 User Manual
Page 40: 1 liquid tank agitation procedure
Advertising
Seed Hawk
®
Manual
Granular and Liquid Tanks
Page 35
5.7 AGITATE LIQUID FERTILIZER
It is recommended that the contents in the liquid fertilizer tank be agitated for a few
minutes before seeding if liquid fertilizer in the tank has sat for more than eight hours.
NOTE: Phosphate is heavier than other nutrients and will tend to settle to the
bottom of the tank.
5.7.1 Liquid Tank Agitation Procedure
1. Open main valve, 1 Figure 35, and close the fill valve, 2 Figure 35.
2. Start fill pump.
3. Run for 2 - 3 minutes and turn off pump.
4. Close valves.
Advertising