9.6.3 Low Alarm Point
This is the minimum meter RPM the monitor will recognize. If the meter RPM falls
below this setting an alarm will sound and must be acknowledged if the condition
is left to continue. The default low alarm point value is 0.5 RPM. If this value is to
be changed, press the SELECT button and “0.5RPM” will be highlighted and can
be changed using the up/down arrow keys. Once the desired value is on the
screen press the SELECT button again and the highlight bar will move to the
“Weight/Rev” bar. When seeding Canola or inoculants at slow speeds (less than
4mph) slow speed alarm maybe triggered.
9.6.4 Weight / Rev
Monitor calculates and enters this value after calibration is completed.
Default is 0 for a new system.