colliding with the touch screen. The screen can be cleaned with a mild detergent and a lint free cloth. Never
use an abrasive cleaner on the display.

1. Securely mount the 880 Enclosure in accordance with Figure 14.

www.detcon.com

11"

13.85"

6.8"

15.2"

15.75"

Ø0.344"

Mounting Hardware

Figure 14 Dimensional Overview

2. Run the serial cable between the Main 880 enclosure and the 880 Remote Display enclosures.

3. Connect the RS-422 Serial communications cable to the terminal blocks labeled “REMOTE

OUTPUT” in the Main 880 enclosure (Figure 15).

TXD+

TX

D

-

RXD+

REMOTE

OUTPUT

RXD-

0V

Figure 15 Main 880 terminal blocks and connections


4. Connect the RS-422 Serial communications cable to the input terminal blocks inside the 880 Remote

Display labeled “TERMINAL INPUT” as shown in (Figure 16).