KEPCO ATE-DMG SERIES User Manual
Kepco, Ate-dmg series power supply, Models
O P E R ATO R M A N U A L
IMPORTANT NOTES:
1)
This manual is valid for the following Model and associated serial numbers:
MODEL
SERIAL NO.
REV. NO.
2)
A Change Page may be included at the end of the manual. All applicable changes and
revision number changes are documented with reference to the equipment serial num-
bers. Before using this Instruction Manual, check your equipment serial number to identify
your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu-
mentation Office in New York, (718) 461-7000, requesting the correct revision for your par-
ticular model and serial number.
3)
The contents of this manual are protected by copyright. Reproduction of any part can be
made only with the specific written permission of Kepco, Inc.
Data subject to change without notice.
KEPCO
®
THE POWER SUPPLIER™
KEPCO, INC.
131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
email: [email protected]
World Wide Web: http://www.kepcopower.com
KEPCO INC.
An ISO 9001 Company.
ORDER NO.
REV. NO.
©2014, KEPCO, INC,
P/N 243-1324d
ATE-DMG SERIES
POWER SUPPLY
MODELS
ATE 6-100DMG, ATE 15-50DMG,
ATE 25-40DMG, ATE 36-30DMG,
ATE 55-20DMG, ATE 75-15DMG,
ATE 100-10DMG, ATE 150-7DMG
Document Outline
- SECTION 1 - INTRODUCTION
- SECTION 2 - INSTALLATION
- SECTION 3 - OPERATION
- FIGURE 1-1. ATE-DMG Series Programmable Power Supply
- SECTION 1- INTRODUCTION
- 1.1 Scope of Manual
- 1.2 General Description
- 1.3 Specifications
- 1.4 Local Control
- 1.5 Remote Control
- TABLE 1-1. ATE-DMG D-C Output Ratings and output impedance
- TABLE 1-2. ATE-DMG Series Specifications
- TABLE 1-3. ATE Dynamic Specifications, Resistive Load
- TABLE 1-4. Overvoltage/Overcurrent Settings
- TABLE 1-5. ATE Static Specifications
- 1.6 Features
- 1.6.1 Overvoltage/Overcurrent Protection
- 1.6.1.1 Programmable Overvoltage/Overcurrent Delay
- 1.6.1.2 Crowbar Circuit
- 1.6.2 Non-volatile Storage of Programmed Sequences or Active Settings
- 1.6.3 User-defined Voltage/Current Limits
- 1.7 Equipment Supplied
- 1.8 Accessories
- TABLE 1-6. Accessories
- 1.9 Safety
- TABLE 1-7. Safety Symbols
- FIGURE 1-2. Mechanical Outline Drawing
- SECTION 2 - INSTALLATION
- 2.1 Unpacking and Inspection
- 2.2 Terminations and Controls
- TABLE 2-1. Front Panel Controls, Indicators and Terminations
- FIGURE 2-1. ATE-DMG Full Rack Series Front Panel
- TABLE 2-2. Rear Panel Terminations
- FIGURE 2-2. ATE-DMG Full Rack Series Rear Panel
- TABLE 2-3. Internal Controls and Their Functions
- FIGURE 2-3. Location of Internal Controls
- TABLE 2-4. Input/Output Pin Assignments for Remote Control
- 2.3 Source Power Requirements
- FIGURE 2-4. A-C Input Source Voltage Selection, ATE-DMG Full Rack Series
- 2.4 Cooling
- 2.5 Preliminary Operational Check
- FIGURE 2-5. LCD Power On Defaults
- 2.6 Installation
- 2.6.1 Grounding
- 2.6.1.1 A-C (Safety) Ground
- 2.6.1.2 Isolation from Ground.
- 2.7 Fast Mode Conversion of the Ate Power Supply
- 2.7.1 Precautions.
- 2.7.2 Lag Network Adjustment
- 2.7.3 Crowbar Operation, Fast Mode
- 2.7.4 Manual Change-over, Slow/fast Mode
- FIGURE 2-6. Required Steps for ATE “Fast Mode” Conversion
- 2.8 Operating Configuration
- SECTION 3 - OPERATION
- 3.1 General
- 3.1.1 Safety Grounding
- 3.1.2 D-C (Output) Grounding
- 3.1.3 Power Supply/Load Interface
- 3.1.3.1 Load Wire Selection
- FIGURE 3-1. Typical Output Impedance vs. Frequency Plot for Stabilized d-c Sources
- 3.2 Load Connection
- 3.2.1 General
- FIGURE 3-2. Standard Jumper Link Connections for Local (Front Panel) Control of Output Voltage, Output Current and VP Crowbar Level (Slow Mode)
- 3.2.2 Load Connection, Method I (Local Error Sensing)
- FIGURE 3-3. Load Connection Method I, Local Error Sensing
- 3.2.3 Load Connection, Method II (Remote Error Sensing)
- FIGURE 3-4. Load Connection, Method II Using Remote Error Sensing.
- 3.2.4 Load Connection, Method III
- FIGURE 3-5. Load Connection, Method III
- 3.3 Overvoltage Crowbar, Setup and Check
- 3.3.1 Setup and Check Procedure
- 3.4 Local Mode Operation (Keypad Operation)
- 3.4.1 Front Panel Keypad and LCD
- 3.4.1.1 Command Entry Status
- 3.4.1.2 Data Entry Status
- 3.4.1.3 Display (LCD)
- 3.4.1.4 Keypad Functions
- TABLE 3-1. Key Functions (Continued)
- 3.4.2 Turning the Power Supply On
- FIGURE 3-6. LCD Power On Defaults
- 3.4.3 Setting Local Mode
- 3.4.4 Adjusting LCD Contrast
- 3.4.5 Enabling/Disabling Audible Beeps
- 3.4.6 Enabling/Disabling DC Output Power
- 3.4.7 Reset
- 3.4.8 Setting Output Voltage or Current
- 3.4.9 Setting Overvoltage or Overcurrent Protection
- 3.4.10 Changing Protection Delay
- 3.4.11 Changing Maximum Voltage or Current Value
- 3.4.12 Storing Power Supply Output Settings
- 3.4.13 Recalling Stored Output Settings
- 3.4.14 Enabling Remote Analog Control
- 3.4.15 Local Mode Programming of the Power Supply.
- 3.4.15.1 Creating or Modifying a Program (Program Edit Mode)
- 3.4.15.1.1 Modifying Programmed Time Interval
- 3.4.15.1.2 Time Interval Accuracy
- 3.4.15.1.3 Display Program Option
- 3.4.15.2 Running a Program
- 3.4.15.3 Stepping Through a Program
- 3.4.15.4 Cycling a Program
- TABLE 3-2. Memory Location Worksheet
- 3.4.15.5 Running a Program Once
- 3.4.15.6 Stopping a Program
- 3.4.15.7 Stopping a Running Program
- 3.4.15.8 Sample Program
- TABLE 3-3. Sample Program (Model ATE 25-40DMG)
- 3.4.16 Calibration
- 3.5 Analog Remote Programming
- FIGURE 3-7. A11 Assembly Connector and Pin Locations
- TABLE 3-4. Connector A11J5 Pin Functions
- 3.6 Digital Remote Mode Programming
- 3.6.1 IEEE 488 (GPIB) Bus Protocol
- TABLE 3-5. IEEE 488 (GPIB) Bus Interface Functions
- TABLE 3-6. IEEE 488 (GPIB) Bus Command Mode Messages
- TABLE 3-7. IEEE 488 (GPIB) Bus Data Mode Messages
- 3.6.2 DCL Control
- 3.6.3 Changing the GPIB Address
- 3.6.4 Enabling Remote Analog Control
- 3.6.5 Programming Techniques to Optimize performance
- 3.7 SCPI Programming
- 3.7.1 SCPI Messages
- 3.7.2 Common Commands/Queries
- 3.7.3 SCPI Subsystem Command/Query Structure
- 3.7.3.1 ABORt Subsystem
- 3.7.3.2 DIAG Subsystem
- 3.7.3.3 DISPlay Subsystem
- 3.7.3.4 INITiate Subsystem
- 3.7.3.5 LIST Subsystem
- 3.7.3.6 MEASure Subsystem
- 3.7.3.7 OUTPut Subsystem
- 3.7.3.8 Protection Subsystem
- 3.7.3.9 STATus Subsystem
- 3.7.3.10 TRIGger subsystem
- 3.7.3.11 [SOURce:]VOLTage and [SOURce:]CURRent Subsystems
- 3.7.3.12 CALibrate Subsystem
- 3.7.4 Program Message Structure
- FIGURE 3-8. Tree Diagram of SCPI Commands Used with ATE-DMG Power Supply
- 3.7.4.1 Keyword
- TABLE 3-8. Rules Governing Shortform Keywords
- FIGURE 3-9. Message Structure
- 3.7.4.2 Keyword Separator
- 3.7.4.3 Query Indicator
- 3.7.4.4 Data
- 3.7.4.5 Data Separator
- 3.7.4.6 Message Unit Separator
- 3.7.4.7 Root Specifier
- 3.7.4.8 Message Terminator
- 3.7.5 Understanding The Command Structure
- 3.7.6 Program Message Syntax Summary
- 3.7.7 SCPI Program Examples
- FIGURE 3-10. Typical Example of ATE-DMG Power Supply Program Using SCPI Commands
- APPENDIX A - IEEE 488.2 COMMAND/QUERY DEFINITIONS
- TABLE A-1. IEEE 488.2 Command/query Index
- A.2 *CLS — Clear Status Command
- A.3 *ESE — Standard Event Status Enable Command
- TABLE A-2. Standard Event Status Enable Register and Standard Event Status Register Bits
- A.4 *ESE? — Standard Event Status Enable Query
- A.5 *ESR? — Event Status Register Query
- A.6 *IDN? — Identification Query
- A.7 *OPC — Operation Complete Command
- A.8 *OPC? — Operation Complete Query
- A.9 *OPT? — Options Query
- A.10 *RCL — Recall Command
- A.11 *RST — Reset Command
- A.12 * SAV — Save Command
- FIGURE A-1. GPIB Commands
- A.13 *SRE — Service Request Enable Command
- TABLE A-3. Service Request Enable and Status Byte Register Bits
- A.14 *SRE? — Service Request Enable Query
- A.15 *STB? — Status Byte Register Query
- A.16 *TRG — Trigger Command
- A.17 *TST? — Self Test Query
- APPENDIX B - SCPI COMMAND/QUERY DEFINITIONS
- B.1 Introduction
- TABLE B-1. SCPI Subsystem Command/query Index
- B.2 ABORt Command
- FIGURE B-1. Programming the Output
- B.3 CALibrate:CURRent:LEVel Command
- B.4 CALibrate:CURRent[:DATA] Command
- FIGURE B-2. Using Calibration Commands and Queries
- B.5 CALibrate:PASSword Command
- B.6 CALibrate:SAVE Command
- B.7 CALibrate:STATus Command
- B.8 CALibrate:STATus? Query
- B.9 CALibrate:VOLTage:LEVel Command
- B.10 CALibrate:VOLTage[:DATA] Command
- B.11 CALibrate:ZERO Command
- B.12 DIAG:EXT Command
- B.13 DIAG:EXT? Query
- B.14 DISPlay:CONTrast Command
- FIGURE B-3. Using Display Commands
- B.15 DISPlay:CONTrast? Query
- B.16 DISPlay:MODE Command
- B.17 DISPlay:MODE? Query
- B.18 DISPlay:TEXT Command
- B.19 DISPlay:TEXT? Query
- B.20 INITiate[:IMMediate] Command
- B.21 INITiate:CONTinuous Command
- B.22 INITiate:CONTinuous Query
- B.23 INSTrument:STATe Command
- B.24 LIST:CURRent Command
- B.25 [SOUR:]LIST:CURRent? Query
- B.26 [SOUR:]LIST:CURRent:PROTect Command
- FIGURE B-4. Using LIST Commands and Queries
- B.27 [SOUR:]LIST:CURRent:PROTect? Query
- B.28 [SOUR:]LIST:DWELl Command
- B.29 [SOUR:]LIST:DWELl? Query
- B.30 [SOUR:]LIST:INDex Command
- B.31 [SOUR:]LIST:INDex? Query
- B.32 [SOUR:]LIST:SEQuence:NEXT Command
- B.33 [SOUR:]LIST:SEQuence:NEXT? Query
- B.34 [SOUR:]LIST:SEQuence:STARt Command
- B.35 [SOUR:]LIST:SEQuence:STARt? Query
- B.36 [SOUR:]LIST:VOLTage Command
- B.37 [SOUR:]LIST:VOLTage? Query
- B.38 [SOUR:]LIST:VOLTage:PROTect Command
- B.39 [SOUR:]LIST:VOLTage:PROTect Query
- B.40 MEASure[:SCALar]:CURRent[:DC]? Query
- B.41 MEASure[:VOLTage][:SCALar][:DC]? Query
- B.42 OUTPut[:STATe] Command
- B.43 OUTPut[:STATe] Query
- B.44 OUTPut:PROTection:DELay Command
- B.45 OUTPut:PROTection:DELay Query
- B.46 PROGram:SELect:STATe Command
- B.47 PROGram:SELect:STATe? Query
- B.48 READ[:SCALar]:CURRent[:DC]? Query
- B.49 READ[:VOLTage][:SCALar][:DC]? Query
- B.50 [SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude] Command
- B.51 [SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude] Query
- B.52 [SOURce:]CURRent:LIMit:HIGH Command
- B.53 [SOURce:]CURRent:LIMit:HIGH? Query
- B.54 [SOURce:]CURRent:[:LEVel]MODE Command
- B.55 [SOURce:]CURRent:[:LEVel]MODE? Query
- B.56 [SOURce:]CURRent:PROTection[:LEVel] Command
- FIGURE B-5. Programming Current
- B.57 [SOURce:]CURRent:PROTection[:LEVel]? Query
- B.58 [SOURce:]CURRent:PROTection:CLEar Command
- B.59 [SOURce:]CURRent:PROTection:TRIPped? Query
- B.60 [SOURce:]CURRent:[:LEVel]TRIGgered[:AMPlitude] Command
- B.61 [SOURce:]CURRent:[:LEVel]TRIGgered[:AMPlitude]? Query
- B.62 [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude] Command
- B.63 [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]? Query
- B.64 [SOURce:]VOLTage:[:LEVel]TRIGgered[:AMPlitude] Command
- B.65 [SOURce:]VOLTage:[:LEVel]TRIGgered[:AMPlitude]? Query
- B.66 [SOURce:]VOLTage:LIMit:HIGH Command
- B.67 [SOURce:]VOLTage:LIMit:HIGH? Query
- B.68 [SOURce:]VOLTage:[:LEVel]MODE Command
- B.69 [SOURce:]VOLTage:[:LEVel]MODE? Query
- B.70 [SOURce:]VOLTage:PROTection[:LEVel] Command
- FIGURE B-6. Programming Voltage
- B.71 [SOURce:]VOLTage:PROTection[:LEVel]? Query
- B.72 [SOURce:]VOLTage:PROTection:CLEar Command
- B.73 [SOURce:]VOLTage:PROTection:TRIPped? Query
- B.74 [SOURce:]FUNCtion:MODE? Query
- B.75 STATus:OPERation:CONDition Query
- TABLE B-2. Operation Condition Register, Operation Enable Register, and Operation Event Register Bits
- B.76 STATus:OPEReration:ENABle Command
- B.77 STATus:OPEReration:ENABle? Query
- B.78 STATus:OPERation[:EVENt] Query
- B.79 STATus:PRESet Command
- FIGURE B-7. Using Status Commands and Queries
- B.80 STATus:QUEStionable[:EVENt]? Query
- TABLE B-3. Questionable Event Register, Questionable Condition Register and Questionable Condition Enable Register Bits
- B.81 STATus:QUEStionable:CONDition? Query
- B.82 STATus:QUEStionable:ENABle Command
- B.83 STATus:QUEStionable:ENABle? Query
- B.84 SYSTem:ERRor[:NEXT]? Query
- B.85 SYSTem:ERRor:CODE? Query
- B.86 SYSTem:ERRor:CODE:ALL? Query
- B.87 SYSTem:KLOCk Command
- B.88 SYSTem:KLOCk? Query
- B.89 SYSTem:LANGuage? Query
- B.90 SYSTem:LANGuage Command
- TABLE B-4. Error Messages
- B.91 SYSTem:PASSword:CENable Command
- B.92 SYSTem:PASSword:CDISable Command
- B.93 SYSTem:PASSword:STATe? Query
- B.94 SYSTem:SECurity:IMMediate Command
- TABLE B-5. Factory Default Calibration Passwords
- TABLE B-6. Master Passwords
- B.95 SYSTem:SET Command
- B.96 SYSTem:VERSion Query
- FIGURE B-8. Using System Commands and Queries