2.9 Mounting
2.9.1 Torques and pressures
Tightening of bolts
• Always tighten the bolts uniformely and in diagonally opposite sequence.
• Do not exceed the maximum torque value.
• Step 1: Apply approx. 50% of max. torque given in table.
• Step 2: Apply approx. 80% of max. torque given in table.
• Step 3: Apply 100% of max. torque given in table.
Maximum torque for 11864-2A flange version
Figure 2-19: Tightening of bolts
CAUTION!
The max. allowable torque depends on the gasket material, see datasheet for detailed
information.
Bolts to be used from material SS, class 70-A2.
Nominal diameter
[mm]
Pressure rating
Bolts
Max. torque
[Nm]
25
PN 40
4x M6
7
40
PN 40
4x M8
16
50
PN 25
4x M8
16
80
PN 25
6x M8
16
100
PN 25
6x M8
16
125
PN 10
6x M10
32
150
PN 10
6x M10
32